    Wear resistant fire resistant plastic is a high-performance material designed for the lining of high-temperature industrial equipment. It has the characteristics of wear resistance, high temperature resistance and thermal shock resistance, and is widely used for repairing or building new linings. So how to use wear-resistant and fire-resistant plastic?

    1.Preparation before construction:

    Before construction, the oil, dust and loose materials on the surface of the substrate must be thoroughly cleaned to ensure that the substrate is dry. If it is a metal surface, V/Y-type anchor nails need to be welded to enhance the bonding strength.

For semi-dry materials, add the binder according to the ratio specified by the manufacturer and then proceed with construction. For dry materials, trap the materials on site before use. Cover the semi-dry materials with plastic sheeting and wait for more than 12 hours to trap the materials. When using, add the remaining binder as semi-dry materials and stir.

    2.Start construction:

    Fill the plastic layer by layer, with each layer 50~100mm thick, and tamp it evenly with a pneumatic pick or a wooden hammer to avoid hollowing. The construction needs to be pushed forward from one side, the joints are staggered, and the new and old interfaces are coated with adhesive. Templates can be used to assist in shaping complex areas. After construction, the surface is scraped flat and a 3~5mm/m expansion joint is reserved.

    3. Curing and baking:

    After construction, let it stand for 24 to 48 hours, and the ambient temperature should be controlled at 5 to 35°C. When it is high in temperature, use a wet cloth to keep it moist and prevent cracking. Baking should be carried out according to the heating curve provided by the supplier: first dehumidify at 100 to 150°C, then slowly increase to 300 to 600°C to promote sintering, and finally increase to the working temperature to form a dense structure. Avoid rapid heating.

    4. Precautions:

    Wear resistant fire resistant plastic should be stored in a covered dry warehouse before construction. They should not be exposed to rain or moisture. The shelf life is six months in a good storage environment. In addition, during construction intervals, the plastic rammed solid should be covered with plastic film to prevent it from drying out or being damaged.

    The correct use of wear resistant fire resistant plastic can significantly extend the life of the equipment, but the process specifications must be strictly followed. Haixin Refractory Materials provides you with professional construction solutions to ensure safety and efficiency.