The pretreatment of fire resistant plastic is a very critical step, which directly affects the construction performance and use effect of the material. The following are important points to note:
Enough Time
The time specified by the manufacturer must be followed. 24 hours is usually a common starting point (especially for cement bonded materials), and some materials (such as phosphate bonded materials) may require 24-48 hours or even longer. Shorter time will result in poor results, and longer time may cause hardening and failure.
Cover Tightly and Moisturize
Cover all material surfaces tightly with wet sacks or wet cloth to prevent moisture evaporation, avoid crusting on the surface and uneven dryness and wetness inside.
Suitable Temperature
It is best to trap the material in an environment of 10℃-30℃. If the temperature is higher than 30℃, the material may harden prematurely and be difficult to construct. If the temperature is lower than 10℃, the trapping effect is slow and may not meet the requirements.
Timed Turning
During the period of trapping, the material needs to be turned over 1-2 times. Turn the outside and bottom to the inside and top. Cover it again immediately after turning it over. Make the moisture and temperature more even and expel the air inside.
Pre-use Inspection
When the material-binding time is up, check whether the overall color and hardness of the fire resistant plastic are uniform, whether it is easy to form a ball without cracking when kneaded by hand, whether it feels flexible and sticky, and whether there are any dry powder balls or lumps.
Warm reminder: Strictly abiding by the material trapping regulations is an important prerequisite for ensuring the construction quality and service life of fire resistant plastic. This step must not be omitted or simplified due to rushing the construction schedule.